Mezzanine floor glossary

The words you will see on mezzanine quotes, drawings and calculations, explained in a sentence or two.

Mezzanine floor
A free-standing intermediate floor built inside a building, usually a bolted steel frame on its own columns, that adds a second level of usable space.
Rack-supported mezzanine
A raised floor or walkway carried by the uprights of storage racking or shelving rather than by separate columns.
Pick module
A multi-level rack-supported structure with walkways and conveyors, used for high-volume order picking.
Primary beam
A main beam spanning between columns, usually a hot-rolled universal beam, that carries the secondary joists.
Secondary beam (joist)
A lighter cold-rolled C or Z-section member spanning between primary beams and supporting the deck.
Universal beam (UB)
A standard hot-rolled I-section steel beam used for primary beams on heavier mezzanines.
Square hollow section (SHS)
A square steel tube commonly used for mezzanine columns.
Base plate
The steel plate welded to the foot of a column and fixed to the floor slab with anchors to spread the column load.
Column grid
The spacing of columns in each direction. A wider grid gives more clear floor below but needs heavier beams.
Clear height
The height available under the mezzanine deck, or between the deck and roof steel above it.
UDL (uniformly distributed load)
A load spread evenly over the floor, stated in kilonewtons per square metre (kN/m²).
Point load
A concentrated load in one spot, such as a pallet leg, machine foot or column on a slab.
kN/m²
Kilonewtons per square metre, the unit for floor loading. 1 kN/m² is roughly 102 kg on every square metre.
Load notice
A sign fixed to a mezzanine stating the safe working load it was designed for.
Deck
The floor surface of the mezzanine, such as high-density chipboard, steel grating or chequer plate.
High-density chipboard
The most common mezzanine deck, usually 38mm thick, laid on steel joists and often with a hard-wearing top surface.
Steel grating
An open steel mesh deck that lets light, air and sprinkler water pass through.
Chequer plate
Steel plate with a raised diamond pattern for grip, used for heavy-duty decks and platforms.
Fascia
The edge trim along the open side of the mezzanine deck, sometimes fire-rated.
Kick plate
An upstand at the edge of the deck that stops items and feet sliding off, also called a toe board.
Pallet gate
A gate at the mezzanine edge that lets pallets be loaded by forklift; up-and-over types keep a barrier closed between people and the edge at all times.
Up-and-over gate
A pallet gate with two linked barriers, so the deck side closes as the loading side opens.
Balustrade
The guarding along an edge or stair, which may be mesh, rails, solid panels or glass.
Approved Document K
Statutory guidance under the Building Regulations covering stairs, guarding and protection from falling.
Approved Document B
Statutory guidance under the Building Regulations covering fire safety, including escape and fire resistance.
Fire-rated ceiling
A tested ceiling system fixed under the mezzanine that protects the structure for a stated time, usually 30 or 60 minutes.
Travel distance
How far someone must walk to reach an escape route or exit, limited by fire safety guidance.
Completion certificate
The certificate issued by Building Control when work has been inspected and meets the Building Regulations.
BS 5395
The British Standard for the design of stairs, used alongside Approved Document K.
Slab
The concrete floor of the existing building that the mezzanine columns stand on.
Plate load test
A site test that measures how much load the ground or slab can take under a steel plate.
Goods lift
A lift for goods only, not passengers, used to move stock between mezzanine levels.